Optional Shadow 8 Control Box Features
- Two cross-checked captive contact stop relay
outputs
- 24VDC power supply for the light curtain heads
- Two key switches for programming fixed blanking
windows
- Dry-contact auxilliary output for non-safety
applications like a beacon or alarm
Shadow 8 Heads Connect Directly to New WPC 1000
and WPC 2000
For press guarding applications, up to
4 pairs of Shadow 8 heads can connect directly to the new
WPC 1000 and
WPC 2000 Wintriss Clucth Brake Controls - with no need
for a separate control box. This reduces both the initial
investment in equipment and the cost of installation.

Connect up to Four Pairs of Heads to One Control
Shadow 8's unique design enables you to protect multiple
sides of a machine using a single control, one pair of
cables, and up to 4 pairs of light curtains in series. You
can protect both the front and back of your equipment as
well as provide horizontal pass-through detection. Even a
large machine can be guarded with up to 202” of protected
zone to a single control providing an economical solution
and minimizing installation time (for either the transmitter
or receiver, the total length of the heads and interconnect
cabling cannot exceed 110 feet).

Programmable Fixed
Blanking
Fixed blanking windows disable one or more beams to allow
stationary objects such as conveyors or work tables to
remain in the sensing field. You simply place
the obstruction between the transmitter and receiver and
turn the key-lock switches on the control. Shadow 8 senses
the presence of the object and “blanks” the obstructed
beams. The Individual Beam Indicators (IBIs) light up to
indicate which beams are blanked. When the object is
removed, the system will not allow the machine to run until
the control has been reprogrammed to “unblank” the beams.
The first or the main segment must have a minimum of 7 to 9
consecutive beams (5.5” to 7”) not blanked based on its
height (e.g., the 12” main segment must have 7 consecutive
beams (5.5”) not blanked) and 2 consecutive beams in each
extension must not be blanked.
Individual Beam Indicators (IBIs)
Floating Blanking Window
Shadow 8 also enables you to set a floating
blanking window, one beam wide, to allow objects smaller
than 1”, such as air-ejected parts, to pass through the
light curtain in a random pattern without interrupting
operation. This can also be useful when air or hydraulic
lines need to pass through the field. You can use both
floating and fixed blanking simultaneously.
3rd Party Verifications
Instead of saying “designed to meet”, at Wintriss we felt it
was important to subject our systems to the toughest third
party certifications. Shadow 8 has undergone independent
testing and certifications by Underwriters Laboratories
(NRTL/C) to CAN/CSA 22.2 No. 14 and CAN/CSA 22.2 No. 0.8 and
by TÜV to Category 4 CE/IEC 61496-1 and CE/IEC 61496-2.
Shadow 8 complies with OSHA 1910.217, ANSI B11.1, ANSI
B11.19, CSA Z142 and CSA Z432.

Helps You Comply with OSHA Lockout/Tagout
Shadow 8 light curtains can eliminate the need to
lockout/tagout during die changes. OSHA regulation 1910.147
states that lockout is not required when the activity is
“routine and integral to production and personnel are
protected by other guarding methods.”
Service And Support
It’s necessary to have a thorough understanding of the
various safety regulations when applying a safety light
curtain system in your application. Both factory personnel
and our representatives keep up with these changes. At your
request we will check out your application and make
recommendations for the proper light curtain configuration
as well as any supplemental guarding that may be required.
All of our light curtain systems carry a 2-year warranty.
If a system does go down, we have a 48-hour turnaround
policy on repairs.

Shadow 8 heads are available in lengths
from 12" to 59" (extensions from 9")
|