PBC-1100R RESOLVER PRESS BRAKE
CONTROL:
Look at some of the standard features
of the PBC-1100R Press Brake Control:
OSHA, ANSI, and CSA compliant
Air Clutch or
Mechanical Clutch Brake.
Dual Processor Press
Clutch/Brake Control.
Interrupted Stroke
Mode w/Indicator.
PCI-100 Operator Interface with plain
English messages.
Speed Compensated Top Stop.
Real Brake Stop Time Monitor.
Four Programmable Limit Switch
Outputs.
Stroke and Position Display.
Parts Counter with Batch Count.
Total Hits Counter.
Self Diagnostics.
- Anti-Repeat
- Anti-Tie Down
- Key Pad Reset Button.
- Supervisor Code.
- Extra Input for Immediate Stop.
- Air Pressure Switch Input.
- On Board Redundant Power Supplies.
- Light Guard Input.
- Light Guard Mute.
- Mute Indicator Output.
- Hand/Foot Input.
- Hand to Foot.
- Treadle Input.
- Off/Inch/Single/Continuous Modes.
- Stroke-Stop Mode.
- Input Status LEDs.
- Relay Coil Status LEDs.
- Relay Contact Status LEDs.
- Optically Isolated Inputs and Outputs.
- 24 vdc Power for External Devices.
- Plug-in Terminals.
- High and Low RPM Settings.
- Motion Detect.
- Speed Check.
- Status Display.
- Auxiliary Stop Output.
- Enclosure Door Lock.
- Ground Indicator.
Press Control/Operator Station in One.
Air Clutch or Mechanical Clutch
Brake.
- The PBC1000 can be used on an air clutch brake that
is operated with two palm buttons or foot switch and
on mechanical press brakes with a mechanical foot
pedal.
Dual Processor Press
Clutch/Brake Control.
-
The PBC1100R press clutch/brake press
control meets or exceeds ANSI B11.1, B11.3, B11.16
(MPIF#47), B11.19 and OSHA 1910.217 including
control reliability. Self- checking dual logic
controllers constantly check each other for
proper operation and component failure. Dual power
supplies and dual relays provide for even more safety.
The actual contacts switching the solenoid valves are
monitored to confirm proper operation. If the
controllers or relays do not agree, press initiation is
inhibited. The systems are designed so that a single
fault in any of its parts does not lead to the loss of
safety function. A dedicated control eliminates the
possibility of reprogramming or by passing safety
features.
Interrupted Stroke Mode
w/Indicator.
-
Provides a quick and easy way to
resume production when an interrupted stroke occurs.
When the press is stopped before completion of a normal
stroke, the red indicator light will illuminate and the
mode automatically changes to the Inch mode. The Message
Center will display the cause of the interrupted stroke
eliminating any guesswork. After the press has been
brought to the top position, the PBC1100R automatically
returns to the original operating mode. Production is
resumed quickly and easily.
|